400W+400W Redundant PSU for 2U

400W+400W Redundant PSU for 2U
model:RA2-G400VP

400W+400W Redundant PSU for 2U

OPERATION TEMPERATURE: 0°C~45°C
ALTITUDE DURING OPERATION:
UP TO 5000M
SHORT LENGTH 217MM
File download

INPUT SPEC.

★Input voltage: 100 - 240Vac Full Range.
★Frequency: 50 - 60 Hz.
★Input Current: 13A for 115VAC, 6A for 230VAC.
★Inrush Current: 30A for 115VAC, 60A for 230VAC.
★Efficiency: The power efficiency shall meet 80PLUS GOLD.
★The minimum power factor shall be 0.95 with full load and input 230Vac/50Hz.

 

OUTPUT WATTAGE

400W 

 

DC OUTPUT CHARACTERISTIC

Output Voltage Min. Current Max. Current Regulation Ripple & Noise
+3.3V 1A 25A ±5% 50mV
+5V 1A 25A ±5% 50mV
+12V 1A 33A ±5% 120mV
-12V 0A 0.8A ±5% 120mV
+5VSB 0.1A 3.5A ±5% 50mV

♦The combined total power from +3.3V and +5V shall not exceed 170W. 

♦The max total power shall not exceed 400W. 

 

FEATURES
★Temperature Range: Operating 0℃ to +45℃, Storage –20℃ to +70℃
★Hold up time: The output voltages stay in regulation at least 18ms with 100% load after loss of AC input.
Over Current Protection 
★Over Voltage Protection 
★Short Circuit Protection            
★Over Temperature Protection
★Safety: To meet UL, TUV, CB, CE, FCC.
★Altitude during operation: Up to 5000m

 

DIMENSION   Outline download

L x W x H:  217 x  82  x 84 (mm)  /  8.54 x 3.23 x 3.31 (inches)

 

SAFETY DOWNLOAD

UL   CB   TUV   CE   FCC

 

PACKAGE & WEIGHT 

MODEL: RA2-G400VP NET WEIGHT GROSS WEIGHT OUTER CARTON DIMENSION
2 SETS / 1 CARTON 6.00KGS 7.00KGS 43 x 31 x 23 CM
13.23LBS 15.43LBS 16.92x12.20x9.05 INCHES